Tel +7 484 394-97-16, Fax: +7 484 394-97-68
Marketing and Sales Department: +7 484 394-97-16
RPE «RADICO» Ltd
High Range Gamma Area Monitor UDMG-206
For supplies to the Russian Federation
Certificates:
- Certificate of conformity №РОСС RU.0001.01АЭ00.40.10.0790, valid till 25.11.2012
- Certificate of measuring tool type approval №37424, valid till 01.01.2015
Purpose:
gamma dose rate measurement in critical conditions (radiation monitoring during accident)
Main features and functions:
- measurement of gamma dose rate, and data display (depending on version) or data output via RS485
- detection unit is operable under all possible accident of BBP reactor.
- automatic self-testing, alarm signal generation, alarm signal display and alarm output via RS485
- built-in control source for workability diagnostics
- three alarm threshold levels (warning level and two emergency levels)
- alarm of measured value "minor change"
- "dry-contact" signal of threshold value is exceeded
- standard (0...20mA / 4...20mA) analog output for measured data transfer to external systems
- standard (0...20mA / 4...20mA) analog input for external device connection and its measured data consideration in algorithms
- detecting unit can be installed at a distance up to 70 m from processing unit
- unified and replaceable components for all "RADSYS" system devices
Performance specification
Measurement range: | 10-3 ÷ 105 Gy/h |
Energy window | 0,06 ÷ 3,00 MeV |
Operating temperature range | IPU: 0 to +55 °С |
Operating pressure range | 84,0 to 106,7 kPa |
Operating humidity range | up to 95 % at +35 °С |
Relative error | 40 % |
Seismic stability | up to 8 points |
Protection index | IP65 |
Dimensions and weight | DU: Ø50,5x440 mm; not more than 4,5 kg |
Measurement chamber volume | 0,1 l |
Cable length between DU and IPU | not more than 85 m |
Corresponds to 3N class requirements according to NP-001-97 (OPB-88/97) | |
Power supply | 220 V |
Power output | 35 VA |
Options |
|