AWS of whole body counter's operator
Purpose:
view, modification and manual input of whole body counter's measurements if it is used as a part of automated personal radiation monitoring system (APRMS)
Functions:
- preliminary parameter setting of spectrometer facility
- ADC connection
- personnel database connection
- preliminary operations on nuclide library setup
- measurement mode parameter configuration
- spectrum files operation
- Personal radiation counters preparation for human radiation measurement
- personnel radiation measurement, including:
- measurement of 60Co content in lungs and monitoring of other radionuclides presence in lungs by means of "Control personal radiation counter" unit
- measurement of radionuclides content in lungs and human body by means of ""Measuring personal radiation counter" unit
- measurement of iodine isotopes in thyroid gland by means of "Iodine personal radiation counter" unit - preparation and print of measured nuclide content reports
- measurement values recording to the database of personal radiation counter
- personal radiation counter certification and verification
- personal radiation counter operation logging
Includes*:
- system unit
- monitor
- printer
- power unit
Performance specification
Protection index according to NP-001-97 (OPB-88/97) | corresponds to 4 class requirements |
Operating temperature range | +10 to +40 °С |
Operating humidity range | up to 80 % at temperature +25 °С and lower, without condensing |
Operating pressure range | 84,0–106,7 kPa |
Weight | not more than 50 kg |
Power supply | ~220 V |
AC power consumption 220 V | not more than 500 W |
UPS life at full charge | not less than 20 minutes |