Dosimeter-radiometer MKS KP-AD6

Purpose:

operating radiation monitoring in wide dose rate range (from background to emergency level) 

Main features and functions:

  • measurement of ambient dose rate equivalent (DRE) and ambient gamma-radiation dose equivalent (DE), flux density of alpha-particles, beta-particles and gamma-ray quantum from polluted surface
  • current value of the measured parameter is displayed at dosimeter screen and pocket PC
  • value binding with place (room) map by means of the pocket PC
  • measured data transfer by GPRS* (by cellular communication means via pocket PC) using encrypted channel to tthe central database and/or operator's workstation
  • Operating temperature range -30 to +55 оС
  • Operating pressure range 60 to 130 оС
  • Operating humidity range up to 95 % at +35 °С

Performance specification

Corresponds to 4 class requirements according to NP-001-97 (OPB-88/97)

Registered gamma radiation energy range, MeV

0,06÷3,00

DRE measurement range, mSv/h

base 6150AD6/H  

10-1÷104

6150AD-t/H (built-in detector)

10-1÷107

6150AD-15/H

10-1÷107

DE measurement range, mSv  

base 6150AD6/H  

10-1÷104

6150AD-t/H (built-in detector)

10-1÷107

6150AD-15/H

10-1÷107

Main relative measurement error: DRE, % (Р=0,95)

±(15+3/Н), where Н – measured DRE value, mSv/h 

Main relative measurement error: DE, % (Р=0,95)                  

±15 

Registered beta-radiation energy range, MeV                   

0,08÷2,00

Beta-particles flux density range, min-1·cm-2 

6150AD-k 

2,0÷2,5×104

6150AD-17

20,0÷2,5×105

Main relative error of beta-particles flux density measurement, % (P=0,95), not more                 

±30 

Registered alpha-radiation energy range, MeV                

4,2÷6,0 

Alpha-particles flux density range, min-1·cm-2

6150AD-k (sensitive area 170 cm2)

3,0 ÷ 3,0×104

6150AD-17 (sensitive area 6,2 cm2)

35,0 ÷ 3,5×105

Main relative error of alpha-particles flux density measurement, % (P=0,95), not more 

±30

OPTIONS

 

  • without PC
  • with pocket PC
  • with notebook
  • portable version with pocket PC, GPS in water-proof case, and SW
  • with detection unit 6150 AD-t/H
  • with detection unit 6150 AD-6/H
  • with detection unit 6150 AD-15/H
  • with detection unit 6150 AD-17
  • with detection unit 6150 AD-k